HANNA® instruments Catálogo General v38

Specifications BL983324 Range 0.0 to 49.9 mg/L (ppm) Resolution 0.1 mg/L (ppm) Accuracy ±2% f.s. at 25 °C (77 °F) TDS Factor 0.5 Temperature Compensation automatic, from 5 to 50°C (41 to 122°F) with β=2%/ºC Calibration manual, with calibration trimmer Dosing adjustable setpoint covers measure range relay relay closes when reading > setpoint dosing contact maximum 2A (internal fuse protection), 250 VAC or 30 VDC overtime dosing relay is disabled if setpoint is not reached within the set time interval. Timer adjustable between aprox. 5 to 30 minutes, or disabled by jumper. Power Supply models “-0”: 12 VDC adapter (included) models “-1”: 115/230 VAC; 50/60Hz input: 10 VA for 115/230 VAC, 50/60 Hz models; 3 W for 12 VDC models; fuse protected; installation category II. Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’) Weight 12 VDC models, 200 g (7.1 oz); 115/230 VAC models 300 g (10.6 oz) Ordering Information BL983324-0 (12 VDC) and BL983324-1 ( 115/230V) are supplied with mounting brackets, transparent cover and quick reference guide with instrument quality certificate. Recommended Probe HI7634-00 EC/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included). HI7634-00/4 EC/TDS probe with internal temperature sensor and 4 m (13.1') cable (not included). HI7634-00/5 EC/TDS probe with internal temperature sensor and 5 m (16.4') cable (not included). BL983324 TDS Mini Controllers • Large Clear LCD • Fire Retardant Casing • Splash-Resistant Cover The BL983324 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) of a process stream that is within the 0.0 to 49.9 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983324 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. The BL983324 uses a 0.5 conversion factor in which 1.0 μS/cm = 0.5 ppm. Adjustable Dry Contact Dosing Relay The BL983324 features a dosing relay that is activated when the reading is above a user programmable set point. Programmable Overdose Protection For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled. Relay Control Override With the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump. Multicolor LED Indicator Multicolor LED indicator allows an operator to quickly check the status of the controller. Green = Meter in measurement mode and reading is below the set point. Orange/Yellow = Reading is above the set point and the relay is activated. Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded. Fuse Protected Dosing Contacts The relay dosing contact is rated for up to a 2A load and is fuse protected. Labeled Termination Connections Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light. See EC/TDS probes and cable lengths on page 15.94; TDS solutions begin on page 5.39; see rear connections on page 15.97 15 Process Instrumentation 15.93 www.hannainst.com | controllers

RkJQdWJsaXNoZXIy MTI3NTM=