HANNA® instruments Catálogo General v38

Specifications BL983315 BL983319 BL983321 BL983329 Range 0.0 to 199.9 mg/L (ppm) 0 to 1999 mg/L (ppm) 0.00 to 19.99 mg/L (ppm) 0 to 999 mg/L (ppm) Resolution 0.1 mg/L (ppm) 1 mg/L (ppm) 0.01 mg/L (ppm) 1 mg/L (ppm) Accuracy ±2% f.s. at 25 °C (77 °F) TDS Factor 0.5 0.65 0.5 0.5 Temperature Compensation automatic from 5 to 50°C (41 to 122°F) with β =2%/ºC Calibration manual, with calibration trimmer Output galvanic isolated 4-20 mA output; accuracy ±0.2 mA; 500 Ω maximum load (BL9833XX-2 only) Dosing adjustable setpoint adjustable setpoint: covers measure range relay relay closes when reading > setpoint relay closes when reading < setpoint relay closes when reading > setpoint relay closes when reading > setpoint dosing contact maximum 2A (internal fuse protection), 250 VAC or 30 VDC overtime dosing relay is disabled if setpoint is not reached within the set time interval. Timer adjustable between aprox. 5 to 30 minutes, or disabled by jumper. external disable input Normally Open: enable / Closed: disable dosing (BL9833XX-2 only) Power Supply models “-0”: 12 VDC adapter (included) models “-1”: 115/230 VAC; 50/60Hz models “-2”: 115/230 VAC, 4-20 mA Output input: 10 VA for 115/230 VAC, 50/60 Hz models; 3 W for 12 VDC models; fuse protected; installation category II. Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’) Weight 12 VDC models, 200 g (7.1 oz); 115/230 VAC models 300 g (10.6 oz) Ordering Information BL983315-0 (12 VDC), BL983315-1 ( 115/230 VAC), BL983315-2 (115/230 VAC, 4-20 mA Output), BL983319-0 (12 VDC), BL983319-1 ( 115/230 VAC), BL983319-2 (115/230 VAC, 4-20 mA Output), BL983321-0 (12 VDC), BL983321-1 ( 115/230 VAC), BL983329-0 (12 VDC), BL983329-1 ( 115/230 VAC), and BL983329-2 (115/230 VAC, 4-20 mA Output), are supplied with mounting brackets, transparent cover and quick reference guide with instrument quality certificate. Recommended Probe HI7634-00 EC/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not incl.). HI7634-00/4 EC/TDS probe with internal temperature sensor and 4 m (13.1') cable (not incl.). HI7634-00/5 EC/TDS probe with internal temperature sensor and 5 m (16.4') cable (not incl.). BL983315 • BL983319 BL983321 • BL983329 TDS Mini Controllers • Models available with 4-20 mA galvanic isolated output with external dosing disable contact • Large Clear LCD • Fire Retardant Casing • Splash-Resistant Cover These compact, panel mounted, process controllers are for measuring total dissolved solids (TDS) of a process stream. The controllers feature a large LCD with protective cover. Users may choose from automatic or manual dosing modes. BL983315: When in automatic mode, the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983315 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. BL983315 uses a 0.5 conversion factor in which 1.0 μS/cm = 0.5 ppm. BL983319: When in automatic mode, the dry contact relay is activated when a reading is below the set point. The relay can be used to supply power to a dosing pump to add fertilizer to a nutrient solution in order to maintain an ideal concentration. BL983319 uses a 0.65 conversion factor in which 100 μS/cm = 65 ppm. BL983321: When in automatic mode, the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower TDS water to flow into a tank being monitored in order to lower its TDS. The BL983321 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. BL983321 uses a 0.5 conversion factor in which 1.00 μS/cm = 0.50 ppm. BL983329: When in automatic mode, The dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. BL983329 uses a 0.5 conversion factor in which 100 μS/cm = 50 ppm. See EC/TDS probes and cable lengths on page 15.94; TDS solutions begin on page 5.39; see rear connections on page 15.97 15 Process Instrumentation 15.91 www.hannainst.com | controllers

RkJQdWJsaXNoZXIy MTI3NTM=