Cloud connectivity The BL131 & BL132 devices can connect to Hanna Cloud using a secured connection. • Ethernet (RJ45) 10/100 Mbps connection • Device identity registry • Policy-based authorization of security keys The instrument will send status information to Hanna Cloud with a defined period. • Readings: pH / ORP / Temperature • Events: Alarms / Warnings / Errors • Peripheral status: LEDs • Last dosed acid and chlorine volumes • GLP info The instrument will send setup information to Hanna Cloud at startup and whenever the setup is changed on the instrument. • Alarm settings • Dosing settings • General settings • System: Meter information (model, FW version, OS version, serial number), Probe information (type, FW version, serial number) The “Remote Hold” mode: • is an emergency mode that can be remotely triggered via web application • in this mode the pumps are deactivated • can be canceled manually from the controller menu Ethernet input BL132 only • Ethernet connector (RJ-45) 10/100 Mbps connection Additional Specifications Pump control • Pump flow control 0.5 to 3.5 L/h (0.13 to 0.92 gal/h) and maximum output pressure 1 atm (14 psi) • Manual control for each pump Password protection • The setup, calibration and log recall features are password protected Storage interface • USB-C GLP • pH / ORP Alarm system • Intuitive alert system based on LED color coded alarm system • Alarm filtering options • Alarm relay control based on user setup filters Alarm relay output SPDT 5A/230 Vac Activated by selectable pH / ORP / Temperature alarm conditions Analog outputs BL131 only • Three configurable analog outputs, 4 to 20 mA, sourcing • Output impedance ≤ 500 Ω • Accuracy < 0.5 % FS} • Galvanic isolation, up to 50 V relative to earth Three digital inputs • Galvanic isolation, powered contact type • One input for low level in acid / base tank (contact open) • One input for low level in chlorine tank (contact open) • One input for Hold mode (contact open) Single probe input • Probe type: HI1036-18XX* pH / ORP /Temperature / Matching pin, combined digital probe • DIN waterproof connector • Galvanic isolation • RS485 interface Power Supply 100—240 VAC Power Consumption 15 VA Environment • 0-50 °C (32-122 °F) • Max. 95% RH non-condensing Dimensions 245 x 188 x 55 mm (73 mm with pumps); 9.6 x 7.4 x 2.2” (2.9” with pumps) Weight 1700 g (60 oz.) Casing Wall mounted, built-in pump, IP65 rated Ordering Information In-Line Configuration BL131-10 and BL132-10 is supplied with HI1036-1802 Combined electrode (pH / ORP / Temperature), saddle for electrode, Ø 50 mm pipe (1 pc.), fittings for electrode, injector (2 pcs.), saddle for injectors, Ø 50 mm pipe (2 pcs.), peristaltic pump tubing (2 pcs.), PVC aspiration and injection tubing, 10 m, aspiration filter (2 pcs.), 7.01 pH buffer solution, sachet (3 pcs.), 4.01 pH buffer solution, sachet (3 pcs.), 470 mV ORP test solution, sachet (3 pcs.), power cable, probe quality certificate, instrument quality certificate, quick reference guide with QR code for manual download. User Panel Flow Cell Configuration BL131-20 and BL132-20 is supplied with HI1036-1802 Combined electrode (pH / ORP / Temperature), panel mounted flow cell, valve for flow cell connections with fittings and tubing, 10 m, injector (2 pcs.), saddle for valves, Ø 50 mm pipe (2 pcs.), saddle for injectors, Ø 50 mm pipe (2 pcs.), peristaltic pump tubing (2 pcs.), PVC aspiration and injection tubing, 10 m, aspiration filter (2 pcs.), 7.01 pH Buffer solution, sachet (3 pcs.), 4.01 pH Buffer solution, sachet (3 pcs.), 470 mV ORP test solution, sachet (3 pcs.), power cable, probe quality certificate, instrument quality certificate, quick reference guide with QR code for manual download. 15 Process Instrumentation 15.23 www.hannainst.com | controllers
RkJQdWJsaXNoZXIy MTI3NTM=