HANNA® instruments Catálogo General v38

Backlit LCD Display The PCA family has a backlit display that is easy to read from a distance and allows for up to three parameters to be displayed at a time. Nema 4X Protection These analyzers are enclosed in waterproof casing for superior protection against the elements. The front door of the case has a window for the measurement display while also shielding the DPD reagents from UV light to prevent premature degradation. DPD Chlorine Measurement Method The DPD colorimetric method is one of the most common and reliable methods to measure chlorine. The PCA family can use either free or total chlorine reagents and allow for 16,000 measurements to be performed. Reagent Reminder The PCA family has a reagent reminder feature to alert the user when the reagents are running low. When the reagents are changed the counter is reset and the meter automatically tracks the number of readings performed. Colorimeter Diagnostics Advanced diagnostics allow for easy troubleshooting of the colorimeter. In the setup menu it is possible to select an option that allows the user to determine the difference between a dark read (LED off) and a blank read (LED on). These analyzers also automatically perform this check in order to determine when to alert the user that the sample cell needs to be cleaned. Amplified pH/Temperature Probe (PCA320, PCA330, PCA340) An integrated pt100 temperature sensor allows for automatic temperature compensation of pH measurements and allows for monitoring temperature as well. The built in amplifier and matching pin provides for exceptional performance where other probes fail when placed in line with pumps and motors. Data Logging The analyzers can store up to 3500 readings (at least 7 days worth of records when set to a a3 minutes sampling interval) that can be reviewed or downloaded to a Windows compatible PC using the HI92500 software and the RS485 serial port. Logged records contain the date time and reading of all parameters measured along with any alarm status. GLP Data The GLP data allows for the user to review the data and time for the last Chlorine and pH calibration. Digital RS485 Output These analyzers have a RS485 digital output that allows for connection to a Windows compatible PC running the HI92500 software. The software allows for remote monitoring, review of logged data, events and errors, and executing setup options. Two Analog Outputs (PCA340) The PCA340 features two selectable 0-20 or 4-20 mA signal output that are scalable for the transmission of readings to external recording devices. The analog outputs can also be set for dosing and used with dosing pumps that accept a 4-20 mA analog input. The analog outputs can be used for any of the three measured parameters. Two Dosing Relays The dosing relays of these analyzers can be connected to a pH and/or chlorine dosing pumps. The chlorine relays are proportionally controlled while the pH relay can be set for on/off or proportional control. The proportional control offers very fine control of doing to prevent any overshoot and wastage of chemicals. Alarm Relay One SPDT alarm relay is provided that can be activated by adjustable upper and lower chlorine, pH and temperature limits. Error Relay One SPDT error relay is provided and is activated when an error is present including a problem with the colorimeter such as when the reagent counter has reached zero, or when a reading is outside the range for a measured parameter. Warning Messages Error messages are displayed when the reagents are expired or low and if the colorimeter cell needs to be cleaned. 15 Process Instrumentation 15.11 www.hannainst.com | analyzers

RkJQdWJsaXNoZXIy MTI3NTM=