HANNA® instruments Catálogo General v38

Fertilization control Fertilizer can be dosed during irrigation using the Venturi tubes principal or with motorized valves. The control of the quantity of dosed fertilizer can be performed using the volume counters. The system supports dosing from up to 4 fertilizer tanks with specific receipts. The concentration of the fertilizer in irrigation water can be controlled based on the conductivity reading, proportional with irrigation water based on the receipt or ratiometric, in which case the certain quantity of fertilizers are added with the amount of programmed water. pH control The pH control is performed in order to adjust the pH of water to the irrigation program set point. The pH correction can be performed with alkaline or acid solution based on the characteristic of the incoming water. The control of pH and EC is performed with PID, PI or proportional control. The tuning of the PID control can be accomplished by the user manually, or automatically by the PID auto-tuning feature. Agitators and filter cleaning The automatic control of agitators used in fertilizers tanks and filter cleaning system complete the needs of a standard fertigation system. In order to keep the fertilizer concentration constant before and during the irrigation program, the fertilizers are mixed in their tanks based on the agitators program. The system can manage up to two filters mounted to protect the probes and in-line dosing elements. With differential presostates, the filters are monitored and when necessary, the irrigation programs are automatically suspended and washer filter cleaning is started. This process removes any deposits and sediments that may appear on filters to increase the systems life. Redundancy of EC and pH probes For safety reasons, the systems can be equipped with 2 conductivity probes and two pH electrodes in redundancy so that the system can generate an alarm in the case of reading differences between them. A third conductivity probe can be mounted to verify and compensate the incoming water conductivity. Logging system The logging of the controller can be selected on three levels: input reading variations, statistics of reading (average of pH and EC) or events (start of programs, opening valves, …). Alarm system The alarms of these systems are related to measured water quality parameters like conductivity and pH: out of range, differential reading between redundant probes; over dosing of conductivity or acid or alkaline correction solution, tanks at low level or no dosing detected by counter movement. Similar alarms can be generated after the units self-diagnostic tests are run. Sensor connections All the sensors: EC, pH, temperature are connected to the controller via transmitters. pH and EC are temperature compensated on the transmitter level. The output of analog transmitters can be calibrated at two points for pH and conductivity. Also, the controller offers a calibration in two points for pH and one point for conductivity. User interface and digital connection The user interface is based on an 4 x 20 character line LCD, organized for settings and consultancy. The UI has multi-language support. The RS232 connection permits the connection to a PC. Internal back-up system The systems internal back-up power system offers a special feature; in the case of losing external power, the controller will stop the irrigations and memorize the irrigation programs that were not performed. The controller will start from the uncompleted programs after power has been restored. The programs will be executed based on their priority level with full respect of the quantity of irrigation water, pH level, and concentration of fertilizers. Additional features that can be found are control of the external power supply and control of mixing of different water sources (clean water, drain irrigation water). 15 Process Instrumentation 15.7 www.hannainst.com | fertigation control systems

RkJQdWJsaXNoZXIy MTI3NTM=