HANNA® instruments Catálogo General v38

14 Temperature 14.9 www.hannainst.com | thermocouple thermometers *K-type thermocouple probes should be ordered separately to meet your specific application. HI93531 · HI93531N 0.1° Resolution K-Type Thermocouple Thermometers • HOLD · HOLD function • BEPS · Alerts the user of low battery power that could adversely affect readings • Battery indicator · Battery life indicator at startup • Backlight · Backlit display (N and R versions) • Waterproof · Compact, heavy-duty and waterproof • Connectivity · PC and printer compatible (R version) These waterproof thermometers feature 0.1° resolution in the -149.9 to 999.9°C (-24.9 to 999.9°F) range, making them ideal for precise temperature measurements. The instruments display the current temperature along with the minimum and maximum extremes achieved. The HOLD button freezes the display to allow the user time to record readings. The °C/°F button switches between the Celsius and Fahrenheit temperature scale. The CLR button restarts the evaluation of high and low values. The HI93531N features a user-activated backlight for low or no light conditions. The CAL button allows a simple one-point calibration in an ice bath at 0°C when probe interchange occurs. The instruments are equipped with BEPS (Battery Error Prevention System), which alerts the user in the event that low battery power could adversely affect readings. Thermocouple probes begin on page 14.11 Specifications HI93531 HI93531N Range -200.0 to 999.9°C; 1000 to 1371°C -328.0 to 999.9°F; 1000 to 2500°F Resolution 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (outside) 0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F); 0.3°F (-328.0 to -250.0°F); 1°F (outside) Accuracy ±0.5°C (-100.0 to 999.9°C); ±1°C (outside); ±1°F (-148.0 to 999.9°F); ±1.5°F (outside) (for 1 year, excluding probe error) Probe HI766 series K-type thermocouple (not included)* CAL Button N/A yes Backlit LCD N/A yes RS232 N/A N/A Battery Type / Life 1.5V AA (3) / approximately 500 hours of continuous use (with backlight off); auto-off after 60 minutes of non-use (can be disabled) Environment -10 to 60°C (14 to 122°F); RH max 100% Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’) Weight 235 g (8.3 oz.) Ordering Information HI93531 and HI93531N are supplied with batteries and instructions. Probes* HI766C Penetration, stainless steel K-type thermocouple temperature probe with 1 m cable HI766D Air/gas, stainless steel K-type thermocouple temperature probe with 1 m (3.3’) cable HI766E1 General purpose/penetration, stainless steel K-type thermocouple temperature probe with 1 m (3.3’) cable Accessories HI710007 blue shockproof rubber boot HI710008 orange shockproof rubber boot

RkJQdWJsaXNoZXIy MTI3NTM=