HI93102 Meter for Water Analysis Turbidity, Cl , pH, Br, Fe, I and CYAC • Custom calibration points · Advanced electronics allow operators to calibrate the meter • Logging · Log and recall up to 25 different samples. The most important parameters needed for water analysis, especially in drinking water, can be measured with Hanna’s HI93102 portable meter. This instrument not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron, and cyanuric acid (CYAC). Achieve laboratory results in the eld quickly and easily. Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor. In colorimetric mode, users can select between factory pre-programmed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample. Up to 25 measured samples can be stored in memory, together with time and date. Miniaturization of the electronics has made it possible to oer unsurpassed accuracy and quality in a portable unit weighing just one pound. † 1 NTU (Nephelometric Turbidity Unit) = FTU (Formazine Turbidity Unit) * set of 300 tests available, -03 ** set of 150 tests available, -03 Specifications HI93102 Parameter Specifications Turbidity Br—Bromine Range 0.00 to 50.0 NTU† 0.00 to 8.00 mg/L (ppm) Resolution 0.01 (0.00 to 9.99) and 0.1 NTU (10.0 to 50.0) 0.01 mg/L (ppm) Accuracy @25°C ±0.5 NTU or ±5% of reading (whichever is greater) ±0.08 mg/L (ppm) ±3% of reading Free and Total Chlorine CYAC—Cyanuric Acid Range Free: 0.00 to 2.50 mg/L (ppm); Total: 0.00 to 3.50 mg/L (ppm) 0 to 80 mg/L (ppm) Resolution 0.01 mg/L (ppm) 1 mg/L (ppm) Accuracy @25°C ±0.03 mg/L (ppm) ±3% of reading ±1 mg/L (ppm) ±15% of reading I—Iodine Fe LR—Iron LR Range 0.0 to 12.5 mg/L (ppm) 0.00 to 1.00 mg/L (ppm) Resolution 0.1 mg/L (ppm) 0.01 mg/L (ppm) Accuracy @25°C ±0.1 mg/L (ppm) ±5% of reading ±0.02 mg/L (ppm) ±3% of reading pH Range 5.9 to 8.5 pH Resolution 0.1 pH Accuracy @25°C ±0.1 pH Additional Specifications Turbidity Calibration two-point; selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended) Light Source / Detector pure green LED / silicon photocell (2) Battery Type / Life 1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes of non-use Environment 0 to 50°C (32 to 122°F); RH max 95% (non condensing) Dimensions / Weight 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.) Ordering Information HI93102 is supplied with measurement cuvette cap, batteries and instruction manual. See page 12.25 for standards and accessories 12 Turbidity EPA meters 12.16 | www.hannainst.com
RkJQdWJsaXNoZXIy MTI3NTM=