HANNA® instruments Catálogo General v40

pH digital electrodes begin on page 2.147; pH and ORP solutions begin on page 2.160 * limits will be reduced to actual probe limits † standard mode only Specifications HI2600 pH (with included pH probe) Range* -2.00 to 16.00 pH; -2.000 to 16.000 pH† Resolution 0.01 pH; 0.001 pH† Accuracy (@25°C/77°F) ±0.01 pH; ±0.002 pH† Calibration automatic, up to three points (five points†) calibration, 5 standard (7 standard†) buffers available (1.68†, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45†) and two custom buffers† Temperature Compensation* automatic, -5.0 to 100.0°C (23.0 to 212.0°F) (using the built-in temperature sensor) Electrode Diagnostics standard mode: probe condition, response time and out of calibration range mV pH (with included pH probe) Range ±1000 mV Resolution 0.1 mV Accuracy (@25°C/77°F) ±0.2 mV EC (with compatible EC probe) Range 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm absolute EC** Resolution 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm Accuracy (@25°C/77°F) ±1% of reading (±0.05 µS/cm or 1 digit, whichever is greater) Calibration single cell factor calibration; six standards available: 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm, one point offset: 0.00 µS/cm Temperature Coefficient 0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C TDS (with compatible EC probe) Range 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L; 15.0 to 100.0 g/L; up to 400.0 g/L absolute TDS using 0.80 conversion factor** Resolution 0.01 mg/L (ppm); 0.1 mg/L (ppm); 1 (ppm); 0.01 g/L; 0.1 g/L Accuracy (@25°C/77°F) ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) Calibration through EC calibration TDS Factor 0.40 to 0.80 (default value is 0.50) Salinity† (with compatible EC probe) Range 0.0 to 400.0 % NaCl; 2.00 to 42.00 PSU; 0.00 to 80.00 g/L Resolution 0.1 % NaCl; 0.01 PSU; 0.01 g/L Accuracy (@25°C/77°F) ±1% of reading Calibration PSU and g/L through EC calibration; % NaCl — one-point with HI7037 sea water standard Dissolved Oxygen (with compatible DO probe) Range 0.00 to 45.00 ppm (mg/L); 0.0 to 300.0 % saturation Resolution 0.01 ppm (mg/L); 0.1 % saturation Accuracy ± 1.5% of reading ±1 digit Calibration one or two-point at 0% (HI7040 solution) and 100% (in air) Temperature Compensation ATC (0 to 50°C; 32.0 to 122.0°F)* Salinity Compensation 0 to 40 g/L (with 1 g/L resolution) Pressure Compensation -500 to 4000 m (-1640 to 13120') (with 100 m (328') resolution) Temperature Range* -20.0 to 120.0°C; -4.0 to 248.0°F Resolution 0.1°C; 0.1°F Accuracy ±0.5°C; ±0.9°F Additional Specifications Probe (included in HI2600) HI11310 digital glass body pH electrode with 3.5 mm (1/8”) connector and 1 m (3.3’) cable Logging up to 1000† (400 for basic mode) records organized in: manual log-on-demand (max. 200 logs), manual log-on-stability (max. 200 logs), interval logging† (max. 600 samples; 100 lots) Connectivity 1 USB-C port for storage, charging, and PC connectivity Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Power Supply Rechargeable battery via USB-C Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) Weight Approximately 850 g (1.87 lbs.) Ordering Information HI2600 pH/EC/DO benchtop meter includes HI11310 glass body refillable pH electrode, pH 4 buffer solution sachets (2), pH 7 buffer solution sachets (4), pH 10 buffer solution sachets (2), electrode cleaning solution sachets (2), electrode holder, 1.5 m USB-C to C USB-C cable. All HI2600 series compatible pH, EC and DO digital probes are interchangeable with HI2600 and can be ordered separately. USB-C Port for Charging and Data Transfer The HI2600 features a streamlined USB-C port that facilitates charging the integrated rechargeable battery, transferring data to your computer, and exporting œles directly to a ±ash drive. HI2600 Rear View Digital Probe Input Simply connect each probe via the 3.5 mm jack, Digital Smart Electrodes are automatically recognized. 2 pH 2.19 www.hannainst.com | benchtop

RkJQdWJsaXNoZXIy MTI3NTM=